Precision Mode Settings – in Options
Record on Precision mode
Recording Type Recording by Rec, with Precision mode
- [Single] Record until screen OFF, power key, or Alternative Finish Key (setting as below).
- [Till Gap] In addition to [Single], detecting input gap (time no touched) will finish recording.
- [Progress] Record until the same with [Single]. The record will be split by input gap.
Interval regarded as input gap Threshold of input gap for Recording Type [Till Gap] and [Progress].
Generate Wait Image Generate Image control for each taken screenshot, and followed touch point in recording. The generated controls are set as SKIPPED state.
On Success of generated image Generate Image control’s initial setting value for On success, skip / set next wait.
Edit after Recording Open summary edit panel on recording finish.
Save Simple Data To enable replaying with Simple mode, add the data for Simple mode if possible.
* In Simple mode, the fast move will be dropped. Key pushing or complicated multi-touch cannot be played in Simple mode.
Alternative Finish Key Additional key to finish recording.
Replay on Precision mode
Default Interruption Default setting to interrupt playing.
Interrupting Operation Operation to interrupt playing.
- Touch Only touching will interrupt playing operation.
- Any Any input (touchscreen, key, etc.) will interrupt playing operation.
Screenshot on Precision mode
Save Screenshot on Record Take and save screenshot in recording.
Screenshot Method
- Auto Select The method will be set depends on the environment.
- PNG Take screenshot by debug command with PNG type.
- BMP Take screenshot by debug command with BMP type.
- Screen API Android’s screen capturing API.
Screen Rotation Rotation of screenshot by FRep2. Try switching only when the rotation of the screenshot taken by FRep2 is incorrect.
Screenshot Transfer Method for screenshot transfer for PNG or BMP method. (for support)
Retry on Shot Fail Retry once if taking screenshot fails for PNG or BMP method. (for support)
Misc.
Detect Keep Pushing Keep recording while key push or touch continues. Try switching OFF this, only when the device cannot detect gap.
Adjust TrackingID Adjust the signal when multiple TrackingIDs are assigned for single slot. (for support)
Clean up touch signals The method to clean up touch signals after replaying touch operation. Only when the touch remains after finishing/interrupted replay, try to set Reassign all slots.
- Auto Use default option for current app version.
- Reset only used slots Put touch up signals for only used touch slots.
- Reset all slots Put touch up signals for all touch slots.
- Reassign only used slots Put assign and up signals for only used touch slots.
- Reassign all slots Put assign and up signals for all touch slots.
- Reassign used slots on interruption Only when the replay is interrupted, put assign and up signals for only used touch slots. On normal replay finish, same with Reset only used slots.
- Reassign all slots on interruption Only when the replay is interrupted, put assign and up signals for all touch slots. On normal replay finish, same with Reset only used slots.
Use hover signals The hover setting for zero pressure touch signal. Auto will apply the result of Calibrate Input.
Complement UP signal The setting for specific rule of touch signal. If the replay does not reproduce touching UP (releasing finger), try On.